Applications
Data Center network| Optical system access network| Storage area networking fiber channel| High density architectures
MTP®/MPO Harness Cable
12F up to 144FBreaks out to LC/SC/FC/STStandard / Elite
Features
- 100% pre-terminated and tested in factory to ensure transfer performance
- Rapid configuration and networking, reduce installation time
- Supports 40G and 100G network applications
- Jacket material: LSZH, OFNR, OFNP available
- Supports up to 12F, 24F, 48F, 72F, 96F, 144F, customized products are available
Optical Performance
| Connector | Mode | Endface | Standard | Elite |
| IL (max) (dB) | RL (min) (dB) | IL (max) (dB) | RL (min) (dB) |
| MTP®/MPO | SM | 12F/APC | ≤0.70 | ≥60 | ≤0.35 | ≥60 |
|---|
| 24F/APC | ≤0.75 | ≥60 | ≤0.35 | ≥60 |
| 48F/APC | ≤0.75 | ≥60 | — | — |
| MM | 12F/PC | ≤0.50 | ≥30 | ≤0.35 | ≥30 |
|---|
| 24F/PC | ≤0.50 | ≥30 | ≤0.35 | ≥30 |
| 48F/PC | ≤0.50 | ≥30 | — | — |
| LC/SC/FC/ST | SM | APC | ≤0.30 | ≥60 | ≤0.15 | ≥60 |
|---|
| UPC | ≤0.20 | ≥50 | ≤0.15 | ≥50 |
| MM | PC | ≤0.20 | ≥30 | ≤0.15 | ≥30 |
|---|
| Custom | Other fiber counts and performance requirements available on request |
Note:
1. Test wavelength: SM@1310/1550nm, MM@850/1300nm;
2. Standard conformance: GR-326, GR-1435.
Mechanical Properties
| Item | Criteria | Conformance |
| ΔIL After 50 Matings | MTP®/MPO | ≤0.3dB | GR-1435 |
| ΔIL After 500 Matings | LC/SC/FC/ST | ≤0.2dB | IEC 61300-2-2 |
| Min Bend Radius (Dynamic) | 20×OD (Cable Diameter) | |
| Min Bend Radius (Static) | 15×OD (Cable Diameter) | |
Environment Conditions
| Item | Criteria | Conformance |
| Operation Temperature | -20 ~ 70°C | IEC 61753-1 |
| Storage Temperature | -40 ~ 85°C |